Low Voltage System LFP Battery Module 51.2V 105Ah

ASW3000H-S2 ASW3680H-S2 ASW4000H-S2 ASW5000H-S2 ASW6000H-S2
PV Input Max. PV array power 5500 Wp STC 6180 Wp STC 6500 Wp STC 7500 Wp STC 9000 Wp STC
Max. input voltage 550 V
MPP voltage range / rated input voltage 40 V to 530 V / 380 V
Min. input voltage / start voltage 40 V / 50 V
No. of independent MPPT trackers / strings per MPPT input 2 / 1
Max. input current per MPP tracker 16 A
Max. short-circuit current per MPP tracker 20 A
Battery input Nominal battery voltage 48 V
Battery voltage range 40 V to 60 V
Max. charging / dischargingpower 5000 W / 5000 W
Max. charging current / Max. discharging current 100 A / 100 A
Battery type Li-Ion
Battery type ZEN Eco-series
AC output AC voltage range / Nominal AC voltage 180 V to 280 V / 230 V
Rated AC grid frequency 50 Hz / 60 Hz
AC grid frequency range 50 Hz±5Hz / 60 Hz±5Hz
Rated active power 3000 W 3680 W 4000 W 5000 W*¹ 6000 W
Rated apparent power 3000 VA 3680 VA 4000 VA 5000 VA*¹ 6000 VA
Max. apparent power 3000 VA 3680 VA 4000 VA 5000 VA*¹ 6000 VA
Rated grid output Current (@230V) 13.1 A 16 A 17.4 A 21.7 A*² 26.1 A
Max. grid output current 13.6 A 16 A 18.2 A 22.7 A*² 27.3 A
Harmonics THDi (@ Nominal power) < 3%
AC input Rated grid voltage a.c. 230V
Rated grid frequency 50Hz / 60Hz
Rated apparent power 6000 VA
Max. input apparent power from grid 6000 VA
Rated input current from grid a.c. 26.1 A
Max. input current from grid a.c. 27.3 A
EPS output Nominal output voltage 230 V
Nominal output frequency 50 Hz / 60 Hz
ASW3000H-S2 ASW3680H-S2 ASW4000H-S2 ASW5000H-S2 ASW6000H-S2
EPS output Rated apparent power 5000 VA
Max. output apparent power 5000 VA
Peak output apparent power 7500 VA, 10s
Rated Current (@230V) 26.1 A
Max. output current 22.7 A
Max. switch time 22.7 A
Output THDi (@ Linear load) < 3%
Effi- MPPT efficiency 99.90%
Euro efficiency / Max. efficiency 97% / 97.6%
Max. battery to load efficiency
Safety protection DC-side disconnection device
PV string- / Battery input reverse polarity protection ● / ●
All-pole sensitive residual current monitoring unit
Anti-islanding protection
Ground fault protection
Ground fault protection ● / ●
AC over voltage protection
Protection class (as per IEC 62109-1) / overvoltage category (as per IEC 62109-1) I / AC: III; DC: II
General data Power factor at rated power / adjustable displacement ≥0.99 /0.8 leading to 0.8 lagging
Dimensions (W / H / D) 494/420 / 195 mm
Device weight 21.5 kg
Operating temperature range -25 °C … +60 °C
Noise emissions (typical) 30 dB(A)
Standby consumption < 10 W
Cooling concept Natural convection
Degree of protection (as per IEC 60529) IP66
Climatic category (according to IEC 60721-3-4) 4K4H
Max. permissible value for relative humidity (non-condensing) 100%
Max. operating altitude 4000m (>3000m power derating)
Features User interface LED & App
Communication with BMS RS485 / CAN
Communication with meter RS485
Communication with portal WIFI stick
Other communication DRM
Integrated power control / Zero export control ● / ●
● Standard features / ○ optional features / – not available
*1 For VDE-AR-N4105,Smax=Sn=4600VA,Pn=4600W
*2 For AS/NZS4777.2,Iac max=21.7 Version: March 2022